WPS variable change checker
Compare an operating change against the correct prequalified WPS or PQR route.
Choose the conditions to see the result.
Share your project details and supporting records. We’ll review the route and scope before preparation.
Scope & references AWS D1.1 / D1.1M:2025
2025 base edition with July 28, 2026 errata. AMD1 not included.
Compare PQR test variables and qualified ranges independently from nominal WPS values. Enter one categorical variable at a time; unknown process-specific Table 6.6 cases remain unknown.
Prequalified WPS
Table 5.5 tolerances maintain the written WPS: amperage ±10%, voltage ±15%, travel speed ±25%, non-amperage-controlled wire-feed speed ±10%; shielding gas flow +50%/-25%. Numeric checks apply only where Table 5.5 lists the variable for that process.
PQR-qualified WPS
Table 6.6 triggers: amperage ±10% SAW/GMAW/FCAW and ±25% GTAW; voltage ±7% SAW/GMAW/FCAW; travel speed ±15% SAW / ±25% GMAW-FCAW / ±50% GTAW; non-amperage-controlled wire feed ±10%; gas flow >+50%/-20% for GMAW/FCAW-G/GTAW. Process-specific rows/footnotes apply.