CAVOREN WPSAWS D1.1 WPS preparation

Edition and update basis

AWS D1.1 edition basis for WPS preparation

These pages and the prepared rule set use a stated edition and errata set. A project is reviewed to the edition required by its contract.

Current stated basis: AWS D1.1/D1.1M:2025 base edition plus the registered errata dated July 28, 2026. AMD1 is not included. If the contract specifies a different edition, that edition governs the project and must be checked against the relevant rules before the WPS is prepared.

What is included

ItemBasis usedBoundary
Code textAWS D1.1/D1.1M:2025 English base editionBase-edition rules are used.
ErrataRegistered AWS base-edition errata, notice dated July 28, 2026Only corrections applicable to the base edition are included.
Amendment 1AMD1 is not included in this prepared basisAMD1-specific rules or errata are not applied to the base edition.
Project contractThe edition and requirements stated in the governing contractThe project edition takes precedence; the prepared knowledge set must be checked for that edition before use.

Amendment 1 notice reviewed

The official February 16, 2026 Amendment 1 notice identifies a wording correction in Table 8.1's undercut visual-acceptance provision for short welds. It concerns weld acceptance, rather than the procedure-qualification ranges calculated by this site's tools. Those tools do not evaluate undercut acceptance.

On October 8, 2026, we compared every listed instruction in the official AMD1 errata notice with the registered base-edition errata. All 23 AMD1 instructions also appear in the base-edition notice. This notice comparison does not establish that the complete second printing has been reviewed. The stated site basis remains the 2025 base edition with its registered errata; project-specific amendment requirements still need confirmation.

How edition control works

Code year identifies the technical basis. Before a customer WPS is prepared, the governing project specification and contract are checked for the required standard, edition, unit system and added requirements. If a different edition is specified, values or rules from the 2025 base edition are not carried over without verification.

When the edition or amendment is unclear, it is identified as an input to resolve. Confirm the edition from the governing contract.

Technical scope represented here

The prepared knowledge supports two steel WPS preparation routes: a Clause 5 prequalified WPS when all applicable requirements fit, and a WPS based on a customer's applicable existing PQR where qualification support is needed. The PQR route uses traceable qualification records.

  • New qualification tests and supplemental testing are outside the WPS preparation product.
  • Other code editions or amendments require edition-specific review.
  • Specialized scopes such as AWS D1.8 seismic supplements, other welding codes, structural design calculations, and complete field inspection or weld acceptance services are outside this prepared coverage statement.
  • Engineer, client and contract acceptance responsibilities remain with the applicable project parties.

How the rule set is maintained

Requirements come from the applicable AWS code text and official errata. Customer drawings, specifications, material records, PQRs and test reports establish project facts. Manufacturer literature helps identify operating conditions for a particular consumable and process; it does not expand qualification coverage.

Rules are checked with their applicable clauses, tables, figures, notes and units. SI and U.S. customary table values are used as written in their respective systems. A source conflict is kept visible and limits conclusions that depend on that specific item; unrelated conditions can still be assessed.

Official AWS publication information

AWS provides the D1.1/D1.1M:2025 publication listing and links from it to the code's errata and amendment information. Consult the contract, purchased standard and official notices for the applicable project text.

Amendment and errata notices last checked October 8, 2026. AWS publication listings may change; the edition required by the project contract remains controlling.

Continue by WPS route

Thin sheet, piping and ISO terminology: confirm the governing code

Request wordingWhat must be resolvedCurrent service boundary
Thin steel / sheet steelApplication, exact thickness, material and contract's D1.1 or D1.3 designationDo not select the governing code from thickness alone or assume every thin steel detail is a D1.1 order. A D1.3 procedure is outside the current offer.
Pipe or tubular WPSStructural member/butt or T/Y/K connection versus pressure/process piping, plus the specified construction codeApplicable D1.1 structural tubular work can use Clause 10. ASME/API piping or pressure-vessel procedures are separate scope.
WPQR / WPAR / ISO WPSThe exact standard, edition, qualification organization and original test recordWPQR commonly denotes an ISO procedure qualification record; a similar acronym does not make it a D1.1 PQR. ISO procedure preparation is outside this offer. Any acceptance of another standard under 6.2.1.2 requires the responsible Engineer's decision.

Send the actual contract welding specification with the intake information. Resolve the governing code before preparing the document.